Scott Cannon (scott_c) Username: scott_c Registered: 05-2006 |
My 212 HD130 is sounding too compressed. Especially during the warm up period, and not as much once the amp get warmed up, but enough to be a problem. Any suggestions on what might be the cause? | ||
Steve Kennedy (admin) Username: admin Registered: 03-2002 |
Has the amp had a full cap job in the last 10 years? Has it had a properly biased new set of tubes in the last few years? I would suspect that the amp may need a cap job or some plate resistors replaced (in addition to a new set of tubes and biasing). Steve | ||
Scott Cannon (scott_c) Username: scott_c Registered: 05-2006 |
Had a partial cap job done, some plate resistors replaced, and new tubes. Must have missed some bad caps. | ||
Steve Kennedy (admin) Username: admin Registered: 03-2002 |
All of the electrolytic caps ought to be replaced at the same time. If some are bad after 25 years, the others are or will be soon! Steve |